Abstract
The potential safety characteristic is expected as one of the advantages of fusion-driven subcritical system (FDS-I) for the transmutation and incineration of nuclear waste compared with the critical reactor. Transients of the FDS-I may occur due to the perturbation of external neutron source, the failure of functional device, and the occurrence of the uncontrolled event. As typical transient scenarios, the following cases were analyzed: unprotected plasma overpower (UPOP), unprotected loss of flow (ULOF), unprotected transient overpower (UTOP). The transient analyses for the FDS-I were performed with a coupled two-dimensional thermal-hydraulics and neutronics transient analysis code NTC2D. The negative feedback of reactivity is the interesting safety feature of FDS-I as temperature increase, due to the fuel form of the circulating particle. The present simulation results showed that the current FDS-I design has a resistance against severe transient scenarios.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Proceedings of the International Conference on Nuclear Engineering (ICONE)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.