Abstract

We compared exhaled breath condensate (EBC) and induced sputum (IS) for assessing inflammation in pulmonary diseases in patients with obstructive lung disease (n = 20), persistent cough >6 months (n = 20), interstitial lung disease (n = 25) and controls (n = 10). EBC was collected by suspending a Teflon perfluoroalkoxy tube installed in an ice-filled container and connected to a polypropylene test tube. IS was recovered after 20' inhalation of 3% saline with an ultrasonic nebulizer, and 300 cells were differentially counted in cytospin Giemsa-stained slides. H(2)0(2) was measured by a method based on oxidation of phenolsulfonphthalein (phenol red) mediated by horseradish peroxidases and H(2)0(2). Pulmonary function tests were performed by conventional methods. H(2)0(2) levels in EBC and % eosinophils in IS were significantly different between groups. A positive and significant correlation was found between % eosinophils in IS and the levels of H(2)0(2) in EBC for each group and for all patients combined.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.