Abstract
ABSTRACT TERRACE inlet risers perforated with circular and slot orifices were tested in the laboratory. The orifice discharge coefficient for a circular orifice in the cylindrical surface of a riser was found to be significantly larger than for a circular orifice in a flat plate. A simple theoretical equation was found to provide good estimates for riser discharge when correct values of discharge coefficient are used. Side orifices should be evenly distributed around the circumference of the riser to reduce vibration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.