Abstract
1. The trend toward convergence of optimal efficiency zones with respect to reduced rotational speed with decreasing\(n_{s_p } \) is confirmed. 2. Reverse flows in the zone between the impeller and guide apparatus and prior to the impeller determine the low level of efficiency and significant instability during the operation of a turbine with a PLG 15/984 impeller in the pump mode. 3. The effect of eddy formation and air entrapment from the surface of the tailrace on the power curve of a horizontal capsule unit in the pump mode is manifested when the depth of the impeller axis is less than 1.2D1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.