Abstract

This study focuses on the complex dynamics of heat dissipation within diaphragm walls during concrete hydration, crucial in construction engineering. Experimental measurements from three sites in Poland, featuring diaphragm walls of varying thicknesses, ranging from 1 to 1.5 meters, were compared to a numerical model. The model, using a Finite Difference Method, incorporated stages of execution of adjacent panels and their thermal influence. The results closely mirrored the measured temperatures, validating the accuracy of its predictions. Despite minor discrepancies, mostly within ±3°C, the method effectively approximated real-life scenarios. Suggestions for model enhancements include incorporating the effect of concrete admixtures and refining the modeling of sequential panel execution. The thermal soil parameters, their possible range, and their impact on hydration heat dissipation in deep foundations emerged as crucial insights. This research serves as a foundation for deeper investigations into early-age behavior in deep foundations, aiming to extend the analysis to stress and strain domains to unravel characteristic cracking patterns observed in diaphragm walls.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.