Abstract
We present 2 cases of "hybrid lung transplant," which included sequentially implanting a living lobar graft to 1 side and a cadaveric graft to the other side. This procedure was approved by the institutional review board at Okayama University Hospital. The 2 recipients were diagnosed with severe idiopathic pulmonary fibrosis, and living donor lobar lung transplant was considered; however, 2 appropriate donors were not available. Therefore, we accepted extended criteria donor lungs with a partial pressure of oxygen/fraction of inspired oxygen ratio of <251 mm Hg. However, 1 of the 2 patients developed grade 2 primary graft dysfunction. The living donor lobar lung had a low volume but was in good condition, which contributed to the patient's recovery after primary graft dysfunction during the perioperative period. The other patient's status of bronchiolitis obliterans syndrome had gradually progressed to grade 3, and only the living donor lung was functioning at that time. However, both patients are alive 5.5 and 4.2 years after lung transplant, respectively. Hybrid lung transplantation may increase patients' chances of receiving transplants because patients are not likely to survive while waiting for ideal donor lungs to become available.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.