Abstract

In this study an atmospheric air plasma reactor was studied for the degradation of HA and THMs in water. Plasma treatment showed significant breakdown efficacies for HA and THMs. At an applied voltage of 80kV about 93% of HA and >70% of THMs were degraded after 15min and 30min treatment time respectively, with the degradation following a first order kinetic model. Plasma induced reactive species including nitrates and H2O2 were quantified in the treated water. The results of FTIR analysis revealed that the molecular structure of HA was altered by the plasma treatment, with a decrease in aromaticity observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.