Abstract

Pentaerythritol tetranitrate (PETN) has trace homolog impurities that can be detected by high-performance liquid chromatography–mass spectrometry. Consideration of observed impurity masses and candidate structures based on known pentaerythritol impurities allows identification of 22 compounds in the data. These are all consistent with either fully nitrated homologs or derivatives substituted with methyl, methoxy, or hydroxyl groups in place of a nitric ester. Examining relative impurity concentrations in three starting batches of PETN and six subsequently processed batches shows that it is possible to use relative concentration profiles as a fingerprint to differentiate batches and follow them through recrystallization steps.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.