Abstract

This paper discusses subdrain outlet condition and performance in Iowa roadways. A forensic test plan was developed and executed during wet summer conditions covering over 230 and 120 drain outlet locations of the newly constructed jointed plain concrete pavement (JPCP) and the hot mix asphalt (HMA) over JPCP sites, respectively. The tufa formation (i.e., calcium carbonate deposits) is the primary cause of drainage outlet blockage in newly constructed JPCP sites using recycled portland cement concrete (RPCC) as a subbase material. Lesser tufa formation from the use of RPCC base in JPCP was observed with the: (a) use of plastic outlet pipe without the gate screen type rodent guard, (b) use of blended RPCC and virgin aggregate materials. The observations of moisture-related surface distresses nearby blocked drainage outlet locations in HMA over JPCP indicates that compromised drainage outlet performance could accelerate the development of moisture-related distresses in HMA over JPCP.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.