Abstract

Concerns of highly cross-linked polyethylene (XLPE) in total knee arthroplasty (TKA) exist regarding fatigue resistance and oxidation, particularly in posterior-stabilized (PS) designs. A prospective cohort study of 114 consecutive PS TKAs utilized conventional polyethylene in 50 knees and second-generation annealed XLPE in 64 TKAs. Clinical (Short-Form 36, Knee Society Scores, and LEAS) and radiographic outcomes were evaluated at a mean of 5years in 103 TKAs. Mean KSS scores were 12 points higher (P=0.01) and SF-36 physical function subset 14 points higher (P=0.005) in the XLPE group. There was no radiographic osteolysis or mechanical failure related to the tibial polyethylene in either group. At 5-year follow-up, no deleterious effects related to highly cross-linked posterior stabilized tibial polyethylene inserts were observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.