Abstract
Efficient Raman conversion in H 2 gas from 0.53 μm to third Stokes (S 3 at 1.58 μm has been demonstrated using an oscillator/ amplifier configuration. Seed radiation from the oscillator controls the divergence of the Stokes beams and a capillary amplifier configuration enhances the conversion. An overall 9% photon conversion efficiency to S 3 is achieved with the S 3 beam divergence twice the diffraction limit. Photon conversion efficiency within the amplifier is ≈ 20%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.