Abstract

In some applications, electronic systems are expected to operate at high ambient temperature (e.g. 150°C). In this paper, we investigate the failure mechanism and microstructure evolution of solder-free (SAC) solder joints at a maximum temperature of 175°C. It is found that no new failure mechanisms are triggered, and that ageing tests for solder can be accelerated at 175°C. In particular, the growth rate of the interfacial intermetallic compound (IMC) is found to be consistent with that observed at lower temperatures.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.