Abstract
Heat transfer and pressure drop have been experimentally investigated in an equilateral triangular channel (Dh = 1.83cm), which can be used to simulate the internal cooling passage near the leading edge of a gas turbine blade. Three different rib configurations (45°, inverted 45°, and 90°) were tested at four different Reynolds numbers (10000–40000), each with five different rotational speeds (0–400 rpm). The rib pitch-to-height (P/e) ratio is 8 and the height-to-hydraulic diameter (e/Dh) ratio is 0.087 for every rib configuration. The rotation number and buoyancy parameter achieved in this study were 0–0.58 and 0–2.3, respectively. Both the rotation number and buoyancy parameter have been correlated to predict the rotational heat transfer in the ribbed equilateral triangular channel. For the stationary condition, staggered 45° angled ribs show the highest heat transfer enhancement. However, staggered 45° angled ribs and 90° ribs have the higher comparable heat transfer enhancement at rotating condition near the blade leading edge region.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.