Abstract

A bunch-length monitor based on detecting the beam spectrum is presented. The monitor comprises a stripline electrode and a heterodyne detector with a switch. The detailed performance of the monitor was examined on a bench as well as with a beam of the TRISTAN main ring. Calibration was carried out at a low beam current. The measured bunch lengths agree well with the calculated values. It has been demonstrated that the monitor can measure an rms bunch length of 3 mm. The repeatability of the measurement was within ±0.2 mm when the bunch length was 5.7 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.