Abstract
Two actively cooled mock-ups with 2mm thick tungsten armor joined to chromium copper alloy by explosive welding were developed, tested and analyzed in ASIPP of China. The heat load limit of the mock-up is 7MW/m2, and delamination was observed along the W/Cu interface. The mock-ups can withstand the maximum heat flux of 6MW/m2. SEM investigations showed that some cracks and failures appeared in filler materials and at copper/filler interface, but intactness was found at tungsten/filler interface. Numerical simulations indicated that if the distance decreases between the vertex of channel and the interface, the mock-up had the better structure reliability due to the reduction of temperature and stress. Under 4MW/m2 heat flux, the mock-up showed good heat transfer capabilities and high joint reliabilities. All these results demonstrate the explosive joining is also an alternative way to realize the W/Cu joint for the plasma facing components.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.