Abstract

In order to obtain the prebreakdown and breakdown data of plain vacuum gaps in the micrometric regime relevant to field emission displays, an automatic experimental system was developed. The dc breakdown characteristics of the gap in the micrometric regime, varying from 25 to 1000 μm, were extensively studied. The experimental results show that the highly finished broad-area metal electrodes withstand fairly high fields in relatively poor vacuum. The dc breakdown strength of a 50 μm gap was more than 220 V/μm at a pressure of 10−5 Torr, while for a 1000 μm gap, the breakdown strength was about 44.5 V/μm for highly polished chrome-steel electrodes, 2 cm in diameter. The breakdown of a narrow (<200 μm) vacuum gap resulted in rapid degradation, with the gap holding-off lower voltages after breakdown. However, a wider gap (500–1000 μm) was found to exhibit conditioning, with the dc breakdown voltage increasing after each successive breakdown. The breakdown characteristics of ideal gaps with very smooth solid electrodes, presented in this work, will define the theoretical limits to which actual gaps can be stressed in a field emission display.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.