Abstract
AbstractUnwanted foaming and liquid bridging inside structured packings have a negative effect on the pressure drop during thermal separation processes. A novel helical design of a packing column for preventing foaming is presented. The effective interfacial area is calculated by numerical simulations. Different designs are analyzed by varying geometrical parameters such as helix pitch, channel opening angle, and number of channels. Different F‐factor values and liquid loads are evaluated. Packings with larger helix pitch exhibited lower pressure drop and reduced effective interfacial area. Smaller channel opening angles increased the pressure drop and promoted unstable flow conditions. The novel packings show lower effective interfacial area than existing structured packings, but no foaming was observed in a wide range of operating conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.