Abstract

This paper reports the heat transfer coefficients in two-pass rotating rectangular channels (AR=1:2 and AR=1:4) with rib roughened walls. Rib turbulators are placed on the leading and trailing walls of the two-pass channel at an angle of 45° to the flow direction. Four Reynolds numbers are considered from 5000 to 40000. The rotation numbers vary from 0.0 to 0.3. The ribs have a 1.59 by 1.59 mm square cross section. The rib height-to-hydraulic diameter ratios (e/Dh) are 0.094 and 0.078 for AR=1:2 and AR=1:4, respectively. The rib pitch-to-height ratio (P/e) is 10 for both cases, and the inlet coolant-to-wall density ratio (Δρ/ρ) is maintained around 0.115. For each channel, two channel orientation are studied, 90° and 45° with respect to the plane of rotation. The results show that the rotation effect increased the heat transfer on trailing wall in the first pass, but reduced the heat transfer on the leading wall. For AR=1:4, the minimum heat transfer coefficient was 25% of the stationary value. However, the rotation effect reduced the heat transfer difference between the leading and trailing walls in the second pass.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.