Abstract

ABSTRACTIn this work, an experimental investigation on heat and fluid flow characteristics of artificially roughened solar air heater duct has been carried out. The roughness and operating parameters covered a range of Reynolds number (Re) from 2000 to 20000, relative roughness pitch (P/e) from 15 to 30, relative rib length (r/g) from 0.4 to 1.0, and relative rib pitch (Pr/P) from 0.2 to 0.8. Other parameters, i.e., relative roughness height (e/D), angle of attack (α), and relative roughness gap are kept constant. Results show that the considerable enhancement in Nusselt number and Thermo-hydraulic performance has been obtained with an increase in friction factor using roughened surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.