Abstract

The physiological heart rate presents a stochastic behavior known as heart rate variability (HRV). In this framework the influence of HRV on the action potential duration (APD) of the atrial myocyte is analyzed in a computer model. We have found that introducing HRV into the myocyte action potential model decreases the APD of the extra beat S2 in an S1-S2 protocol compared to constant heart rate. A possible theoretical explanation for this is also presented and is derived from switched systems theory. It is suggested to consider the myocyte action potential phase 4 and phase 2 as two operation modes of a switching system and analyze the stability of switching between them. Since random switching is known to have a stabilization effect on a switching system, this might explain why HRV has a stabilization effect on the myocyte APD restitution. Implications of this finding include reduced system stability for conditions with low HRV. A possible application for this phenomenon regards artificial pacemakers, where a preset added HRV is predicted to reduce susceptibility to arrhythmias.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.