Abstract

Four formwork support units were experimental studied by heaping load,including three glass fiber mat reinforced thermo plastics (GMT) formwork support units and one 18mm plywood formwork support unit. Compared with 18mm plywood formwork support unit, the vertical poles force distribution in GMT formwork support units were analyzed. The experimental parameter also included vertical poles height difference and their values were follows: 0mm, 2mm and 4mm. The results showed that the vertical poles force distribution are uneven in GMT formwork support unit and vertical pole height differences have influence on their force distribution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.