Abstract

An experimental investigation was conducted to study the behavior of unreinforced masonry (URM) walls retrofitted with composite laminates. The first testing phase included testing 24 URM assemblages under different stress conditions present in masonry walls. Tests included prisms loaded in compression normal and parallel to bed joints, diagonal tension specimens, and specimens loaded under joint shear. In the second testing phase, five masonry-infilled steel frames were tested with and without retrofit. The composite laminates increased the stiffness and strength and enhanced the post-peak behavior by stabilizing the masonry walls and preventing their out-of-plane spalling. Tests reported in this paper demonstrate the efficiency of composite laminates in improving the deformation capacity of URM, containing the hazardous URM damage, preventing catastrophic failure and maintaining the wall integrity even after significant structural damage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.