Abstract

Background: Anterior cruciate ligament reconstruction (ACLR) using a hamstring tendon autograft often results in hamstring muscle strength asymmetry. However, the effect of hamstring muscle strength asymmetry on knee mechanics has not been reported. Hypothesis: Participants with hamstring strength asymmetry would demonstrate altered involved limb knee mechanics during walking and jogging compared with those with more symmetric hamstring strength at least 2 years after ACLR with a hamstring tendon autograft. Study Design: Controlled laboratory study. Methods: There were a total of 45 participants at least 2 years after ACLR (22 male, 23 female; mean time after ACLR, 34.6 months). A limb symmetry index (LSI) was calculated for isometric hamstring strength to subdivide the sample into symmetric hamstring (SH) (LSI ≥90%; n = 18) and asymmetric hamstring (AH) (LSI <85%; n = 18) groups. Involved knee kinematic and kinetic data were collected using 3-dimensional motion analysis during gait and jogging. Peak sagittal-, frontal-, and transverse-plane knee angles and sagittal-plane knee moments and knee powers were calculated. Independent-samples t tests and analyses of covariance were used to compare involved knee kinematic and kinetic variables between the groups. Results: There were no differences in sagittal- and frontal-plane knee angles between the groups (P > .05 for all). The AH group demonstrated decreased tibial internal rotation during weight acceptance during gait (P = .01) and increased tibial external rotation during jogging at initial contact (P = .03) and during weight acceptance (P = .02) compared with the SH group. In addition, the AH group demonstrated decreased peak negative knee power during midstance (P = .01) during gait compared with the SH group, after controlling for gait speed, which differed between groups. Conclusion: Participants with hamstring strength asymmetry showed altered involved knee mechanics in the sagittal plane during gait and in the transverse plane during gait and jogging compared with those with more symmetric hamstring strength. Clinical Relevance: Hamstring strength asymmetry is common at 3 years after ACLR with a hamstring tendon autograft and affects involved knee mechanics during gait and jogging. Additional research is warranted to further investigate the longitudinal effect of these alterations on knee function and joint health after ACLR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.