Abstract

A case of compartment syndrome after haematoma block for a fracture of the distal radius is reported. This seems to be the first report of this complication. A review of the literature revealed seven other cases of compartmental ischaemia reported after fracture of the distal radius, and a haematoma block was used in all the cases where the type of anaesthesia was known. It is suggested that the additional fluid added for a haematoma block can precipitate a compartment syndrome, which may be more common than the scarcity of cases reported would indicate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.