Abstract

Electrical resistivity and induced polarization surveys have been conducted for groundwater exploration at granitic formation. This study discusses the earth materials resistivity and chargeability of granitic for groundwater exploration at IIUM campus. In this study Terrameter model LS2, cables, electrodes, cable connectors, battery and remote cable were used as the tools for measurement. The spacing between electrodes is 5 m and maximum length of spread line is 400 m by using Pole-Dipole protocol. By comparing the resistivity values and the chargeability values, it would be able to provide better interpretation for ground water exploration for granitic rock. The result also shows the important of chargeability to verify the resistivity value for locating the groundwater position.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.