Abstract

High resolution X-ray computed tomography is used to reconstruct the interior of a sample of an insulation system based on mica-paper tapes impregnated with polyester imide resin that is used in ground-wall insulation of a.c. motor – and generator – windings rated 11kV and above. The tomographic volume is post-processed to identify the presence of minute voids, air-bubbles and very low-density zones that can bring-on partial discharges and material deterioration critical for the operative life of the rotating machines. The tomographic volume is segmented into different materials and a computational mesh is built on it. The electrostatic field is simulated under suitable boundary conditions at the copper conductors and at the ground side. The numerical model allows predicting the maximum intensity of the electric field in critical zones and spotting points above the 2.2kV/mm threshold, as derived from experimental partial discharge inception voltage carried out on the coil, yielding an indirect pre-evaluation of the insulating material that can guide the improvement of the manufacturing process (i.e. impregnation taping).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.