Abstract

The purpose of this research was to evaluate the use of a rotating fluidized-bed granulator to produce acetaminophen granules with sufficient binding force between particles and good plasticity in tablets. Ethenzamide and ascorbic acid were used to compare the relationship between granulation and the sample wetness. It was revealed that a blade rotation rate of 300 rpm, inlet air flow rate of 42 m3/hr, and spraying pressure of 1.5 kg/cm3 produced tablets with the best properties. The granule and tablet properties of ethenzamide and ascorbic acid were compared to those of acetaminophen. These compounds showed different wetting behaviors with water and different compression behaviors. With an increase in medicament content, tablet hardness increased except for the ascorbic acid formulation. Capping and sticking were observed in acetaminophen and in ascorbic acid, respectively, and acetaminophen and ethenzamide showed prolonged disintegration time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.