Abstract

The use of good electro-active polyaniline at high pH for immobilizing glucose oxidase is reported. The response current increased with increasing potential from 0.35 to 0.70 V. The maximum response current occurred at about pH 7.0. The relationship between response current and the glucose concentration was linear from 0.005 to 10.0 mmol dm−3. The Michaelis–Menten constant Km', maximum response current imax and the apparent activation energy (Ea) were 31.59 mmol dm−3, 21.28 µA and 32.58 kJ mol−1, respectively. The response currents of the biosensor increased with increasing temperature. The biosensor was characterized by FTIR, UV-Vis spectra and AC impedance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.