Abstract

AbstractLongitudinal and transverse giant magnetoimpedance (GMI) effects in micropatterned ribbons (Metglas® 2714A) with meander structure are investigated. The maximum longitudinal GMI ratio of the ribbons is 180.4% and it presents to HL = 10 Oe and an AC frequency f = 20 MHz. In the range of 0–10 Oe, the GMI sensitivity of ribbons is 8.1%/Oe at 20 MHz. The maximum transverse GMI ratio is much less than the longitudinal one and the position of GMI extreme value is corresponding to higher magnetic field. The difference between the longitudinal and the transverse GMI effect is due to two main reasons: one is the easy axis deviates from the transverse direction of the sample; another is the demagnetizing factor D⊥ effect on the longitudinal permeability. (© 2009 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.