Abstract

The reduction of the vibration and noise of gears is an important issue in mechanical devices such as vehicles and wind turbines. The characteristics of the vibration and noise of gears are markedly affected by deviations of the tooth flank form of micrometer order; therefore, strict quality control of the tooth flank form is required. The gear measuring instrument is generally calibrated by an involute helicoid artefact. In the tooth flank form measurement of the involute helicoid artefact, the setting error of the involute helicoid artefact largely affects the measurement result. The laborious setting operation is required for the calibration of the gear measuring instrument. Therefore frequent calibration of the gear measuring instrument has not been realized. In this study, evaluation method of the gear measuring instrument using multiple-tooth involute helicoid artifact is proposed to reduce the effect of the setting error. The efficiency of this method is confirmed by the measurement simulation using a computer program.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.