Abstract
The irradiation damage in n/sup +/-Si/p/sup +/-Si/sub 1-x/Ge/sub x/ epitaxial diodes and n/sup +/-Si/p/sup +/-Si/sub 1-x/Ge/sub x//n-Si epitaxial heterojunction bipolar transistors (HBTs) by fast neutrons and MeV electrons is studied as a function of fluence and germanium content for the first time. The degradation of the electrical performance of both diodes and HBTs by irradiation increases with increasing fluence, while it decreases with increasing germanium content. The damage coefficient of reverse current for x=0.12 and 0.16 diodes irradiated by neutrons is calculated to be 6.2/spl times/10/sup -21/ and 5.5/spl times/10/sup -21/ n/sup -1/ A cm/sup 2/, respectively. That of h/sub FE/ for electron-irradiated x=0.08, 0.12 and 0.16 HBTs is 7.6/spl times/10/sup -16/, 2.7/spl times/10/sup -16/ and 1.6/spl times/10/sup -16/ s/sup -1/ cm/sup 2/ respectively. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.