Abstract

This paper presents an overview of the geothermal systems on the island of Bali, Indonesia. Physicochemical data of hot springs and shallow geothermal wells were collected from four geothermal locations: Penebel, Batur, Banjar and Banyuwedang. The concentrations for the three main anions varied significantly indicating a different geothermal history. The values for Cl− ranged from 0.1 to 1000mg/L, for HCO3− from 20 to 2200mg/L and for SO42− from 0.1 to 500mg/L. Although the island of Bali is underlain by carbonate rocks, a carbonate host rock for the geothermal reservoirs could not be confirmed, because the (Ca2++Mg2+)/HCO3− molar ratios were approximately 0.4, well below 1.0 and the K/Mg ratios were approaching those of a calc-alkaline rock reservoir. The HCO3− of the thermal waters correlated with Ca2+, Mg2+, Sr2+ and K+ indicating water–rock interaction in the presence of carbonic acid. Phase separation was inferred for the Bedugul and Banjar geothermal systems, because of relatively high B/Cl ratios. Boron isotopes were determined for selected samples with values ranging from δ11B of 1.3 to 22.5‰ (NBS 951). The heavy δ11B of +22.5‰ together with a low B/Cl ratio indicated seawater input in the Banyuwedang geothermal system. The hydrogen and oxygen isotopic composition of the thermal water plotted along the global meteoric water line (GMWL) and close to the mean annual value for precipitation in Jakarta indicating a meteoric origin of the geothermal water. Comparison of the Si, Na/K, Na/K/Ca and Na/Li geothermometers with actual reservoir temperature measurements and physicochemical considerations led to the conclusion that the Na/Li thermometer provided most reliable results for the determination of geothermal reservoir temperatures on Bali. Using this thermometer, the following reservoir temperatures were calculated: (1) Penebel (Bedugul) from 235 to 254°C, (2) Batur 240°C and (3) Banjar 255°C. Due to seawater input this thermometer could not be applied to the Banyuwedang geothermal system. There application of a SiO2 thermometer indicated a reservoir temperature below 100°C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.