Abstract

Qila Bala Hisar is one of the noteworthy places of Peshawar, Khyber Pakhtunkhwa. The fort was constructed on a filled ground during the 18th century and it was renovated several times by the occupants ever since. Recently, due to an earthquake of magnitude 7.3, the upper part of the south-western wall of the fort collapsed. The collapse of the wall was attributed to the failure of the retained slope. This research was undertaken to characterize the slope material, study causal factors of failure and evaluate remedial strategy. The investigation involved conventional field and laboratory testing and geophysical investigation using electrical resistivity technique to evaluate the nature of stratum. Also, X-ray Diffraction and Scanning Electron Microscopy was used to study the slope material at a molecular level to evaluate the existence of swelling potential. The analysis has shown that excessive seepage of water caused by the poor maintenance of runoff and sewage drains is the causal factor triggered by the seismic event. A remedial strategy involving soil nails, micro piles and improvement of the surface drainage is recommended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.