Abstract
This study tested and optimized various methodologies to generate, sample, and characterize GB and GF test atmospheres in an inhalation chamber, particularly at low vapor levels. A syringe drive/spray atomization system produced vapor concentrations at a range of 1–50 mg/m3. A saturator cell was used to generate vapor at sub-lethal concentrations ranging from 1 mg/m3 down to low levels approaching the threshold limit value time-weighted average (TLV-TWA) of 0.0001 mg/m3 for GB. Both generation techniques demonstrated the ability to produce stable vapor concentrations over extended exposure periods. This capability was important to determine sublethal nerve agent effects, such as miosis, for inhalation toxicology studies. In addition, the techniques employed for producing and maintaining low-level agent vapor would lay the foundation for testing less volatile chemical warfare agents such as VX.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.