Low-molecular-weight block copolymers of ethylene oxide and propylene oxide were eluted through two gel permeation chromatography (GPC) systems; (1) tetrahydrofuran (THF) solvent with PLgel; (2) aqueous solvent with TSKgel. The elution volumes of the copolymers in the THF/PLgel system depended predominantly on chain length, whereas those in the water/TSKgel were greatly influenced by composition as well as chain length. The possibility of using GPC in two systems to estimate copolymer composition was explored.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.