Abstract

Barium-impregnated polyethylene spheres (BIPS) were used to assess gastric emptying in medium-sized dogs consuming a commercial kibble ration. Two sizes of spheres were used: 1.5 mm and 5.0 mm in diameter. Ventrodorsal and right lateral recumbent radiographs were taken immediately before and after consumption of the test meal, and then hourly. The lag phase and the time to 25% (GET25), 50% (GET50), and 75% (GET75) gastric emptying of each sized marker were calculated. There was no significant difference between the lag phases of the small and large BIPS. There was a significant difference between the 1.5 and 5.0 markers at GET25, GET50, and GET75 in these medium-sized dogs. In a majority (70%) of the dogs in this study, GET25 of the 1.5-mm marker occurred at 4.73+/-1.44 hours; GET50 (1.5 mm) occurred at 8.29+/-1.62 hours, and GET75 (1.5 mm) occurred at 10.82+/-1.35 hours. The 5.0-mm markers tended to empty erratically and slowly. Four of the eight dogs retained some of the large markers in their stomachs at the end of the study period (24 hours).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.