Abstract
A gas chromatographic method for determination of vapor phase nicotine in environmental tobacco smoke (ETS) was collaboratively studied by 6 laboratories. Nicotine is desorbed from XAD-4 sample tubes with ethyl acetate containing triethylamine and determined by gas chromatography with nitrogen-selective detection. Each collaborator received blind duplicate samples at each of 6 nicotine concentrations. Three concentrations were generated by spiking XAD-4 tubes with known amounts of nicotine; the remaining 3 concentrations were ETS samples obtained in a carefully controlled environmental chamber containing sidestream and exhaled mainstream smoke from 1R4F Kentucky reference cigarettes. Repeatability and reproducibility relative standard deviations ranged from 4.4 to 11.1% and from 7.0 to 11.1%, respectively, for nicotine concentrations evaluated (up to 6 micrograms/cu m). The method has been adopted official first action.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.