Abstract

An experimental program was initiated io determine the extent of fast neutron and gamma ray streaming through the SRL Mark II control and safety rods and to evaluate the adequacy of the shielding provided in these control and safety rods. The methods and procedures used to evaluate these problems are routine and proven for determining gamma-ray and fast neutron dosages using radiation sensitive films and gold foils. The final experimental results indicated that no excessive streaming of either gamma rays or fast neutrons is present above or around the SHE Mark II control and safety rods. The analytical attenuation methods used to calculate the fast neutron and gamma-ray streaming dose rates gave results that compared favorably with the experimental data. Even ihough the agreement was favorable, it cannot be concluded that these analyical methods would be equally valid for other annular geometries. Additional experimental work will be necessary in order to establish the validity for performing similar analysis, but the favorable agreement encourages the use of such methods until other methods are determined. (auth)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.