Abstract

Three leucoreduction filters were evaluated - when used alone or combined with centrifuge leucoreduction (C-LR) - to prevent alloimmune platelet refractoriness in a dog platelet transfusion model. Donor platelet-rich plasma (PRP) or buffy coat (BC) platelets were either filter leucoreduced (F-LR) or F-LR/C-LR, (51) Cr radiolabelled and transfused. Weekly transfusions were given for up to 8 weeks or until platelet refractoriness. Recipients who accepted treated transfusions were then given non-leucoreduced (non-LR) platelets to determine whether donor-specific tolerance had been induced. Acceptance of F-LR PRP transfusions ranged from 29% to 66%. F-LR/C-LR transfusions prepared from PRP were accepted by 92%, from BC by 63% and from pooled PRP by 75% of recipients (p=NS); overall acceptance rate of F-LR/C-LR transfusions was 83%. Tolerance to subsequent non-LR transfusions occurred in 45% of the F-LR-/C-LR-accepting recipients unrelated to DR-B compatibility between donors and recipients (P = 0·18). In a dog platelet transfusion model, acceptance of donor platelets required combining F-LR with C-LR as apparently each process removes different immunizing WBCs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.