Abstract

In this paper, based on the X nuclear power nuclear reactor, the mixture ratio of the nuclear base plate concrete was designed. And the mechanical property test, adiabatic temperature rise test, concrete shrinkage test and durability test were performed. Basic mechanical property and the thermal performance of the nuclear base plate concrete were investigated. The results show as follows: The compressive strength of 28 days was 38.6 MPa. The derived relationship between specific heat (c) and temperatures (θ) was: c =0.0003322θ2- 0.246358θ+1.4571. The derived relationship between adiabatic temperature-rise and age was: Θn=45.45-45.75/ (1+0.00186n) (100/9). The chloride ions migration coefficient was 5.5×10-12m2/s less than 7×10- 12m2/s. All in all, the mixture ratio of the concrete is suitable for pouring the nuclear base plate of Hainan nuclear power plant nuclear reactor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.