Abstract

In this paper, we present an ultrasonic method for measuring the specific gravity of lead-acid battery electrolyte and study its frequency and temperature characteristics. This method uses an improved frequency scanning ultrasonic pulse echo reflectometer with a two-transducer configuration. The velocity and attenuation coefficient (1 to 30 MHz) of electrolytes with different specific gravities (1.05 to 1.30) are obtained at 25 °C. It has been shown that the ultrasonic velocity changes little with frequency, and there is low attenuation at approximately 5 MHz. The velocities of several electrolytes with different specific gravities are measured in the temperature range from 10 to 50 °C. The thermal transient of the measurement cell is analyzed, showing 0.1% accuracy in specific gravity measurement for a steady temperature and 0.5% accuracy under thermal gradient conditions after temperature compensation. This method is suitable for the on-line, rapid, and accurate measurement of the specific gravity of a lead-acid battery electrolyte.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.