Abstract

Fracture toughness of several different materials was measured using chevronnotched short bar and four‐point bend specimens For glass‐ceramic and ceramic samples both specimens gave valid results. Fracture toughness values measured with bend specimens are 5% to 10% higher compared to those of the short bar. Consistent results for glass could be obtained only with short bar specimens. The notch width of the bend specimen affected the stability of crack growth in glass samples. Fracture toughness values measured in the present study are in good agreement with those of the previous studies.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.