Abstract

Extensor mechanism reconstruction with an extensor mechanism allograft (EMA) remains one of the most reliable methods for treating the extensor mechanism deficient total knee arthroplasty. We report 3 patients who were treated with an EMA who sustained a proximal tibial shaft fracture. In all 3 cases, a short tibial component was present that ended close to the level of the distal extent of the bone block. When performing an EMA, it is important to recognize that the tibial bone block creates a stress riser and revision to a long-stemmed tibial component should be strongly considered to bypass this point to minimize the risk of fracture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.