Abstract

A mid-infrared (MIR) laser absorption spectroscopy (LAS) sensor was developed for temperature, CO, NO, and CO2 measurements at 5 kHz in engine-out exhaust. It used fiber-coupled quantum cascade lasers (QCLs) for measuring CO and NO, and an interband cascade laser (ICL) for measuring CO2. Validation tests in a heated gas cell confirmed that the LAS measurements of CO, CO2, NO, and temperature are accurate to within 4.8%, 5.1%, 4.6%, and 3.1%, respectively, at 1–2 atm and 300–1000 K. The LAS sensor was applied to characterize the engine-out exhaust gas of an 8-cylinder gasoline engine in a light-duty truck at operating conditions where commercial instruments lack sufficient time response to quantify important emission dynamics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.