Abstract

The main functions of the Power Control and Distribution Unit (PCDU) in FORMOSAT-5 satellite are to condition energy from the solar arrays and distribute power for all subsystems on the satellite. The Power Relay (PR) module, one of the major modules in the PCDU is to manage the switchover of redundant DC-DC converter sections, secondary power distribution and power protections. The PR module controls power protections which are under voltage (UV) protection and Undervoltage-Lockout (UVLO) detection. UVLO detection monitors primary power voltage with majority voting in PR FPGA. UV detector switches nominal DC-DC converter to redundant DC-DC section, when under voltage happens. Power protection circuits all can be realized by Inverting Bistable Multivibrator. This paper describes protection methods for power and the reliable circuit design implementation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.