Abstract

ABSTRACTIn this present study, the forced convection heat transfer from aluminum foam heat sinks with 10, 20, 40 PPI pore density placed in a discrete form in a partially open cavity were experimentally investigated. Air was used as working fluid. The uniform heat flux was applied to 3 × 3 array of foam heat sinks horizontally mounted in the cavity. The experimental studies were performed for the 3363–9743 range of Reynolds number and the 2.7 x 106 and 7.5 x 106 range of modified Grashof number. The effects of the Reynolds number, the modified Grashof number and the pore density of foam heat sink on the heat transfer were investigated. The results obtained were compared with the results obtained without foam heat sink cases. In addition, the most heated elements within the cavity were identified and solution proposals were presented. In addition, the most heated elements within the cavity were identified and solution proposals were presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.