Abstract

This article proposes a flux-weakening (FW) control for dual three-phase permanent magnet synchronous machine (DTPMSM) based on vector space decomposition (VSD) control, where the output voltage in αβ subplane is employed for voltage feedback in the FW control loop. As the fundamental components are mapped to αβ subplane while the fifth and seventh harmonics are projected to harmonic z <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> z <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> subplane, the FW current from this new control in αβ subplane is sixth harmonic-free regardless of the fifth and sixth harmonics being resulted from the nonsinusoidal back electromotive force (EMF) or inverter nonlinearity. The proposed control is compared with the conventional FW feedback control extended for DT-PMSM, where the FW control is applied to the two sets of three-phase windings separately. The experimental results show that the proposed FW control based on VSD is superior to the conventional FW control in terms of reduction in current unbalance and harmonic currents.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.