Abstract

The flow regimes below an aerator influence directly the air entrainment and the cavitation damage control. Based on the theoretical considerations, the experiments of the aerator for a discharge tunnel were conducted, and the relationships between the flow regime and hydraulic and geometric parameters were investigated. The results showed that, there are two kinds of threshold values for the flow regime conversions. One is Fr1–2 standing for the conversion from the fully filled cavity to the partially filled cavity, and the other is Fr2–3 which shows the change from the partially filled cavity to the net air cavity. Two empirical expressions were obtained for the conversions of the flow regimes, which can be used in the designs of the aerators.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.