Abstract

BackgroundFloral temperature has important consequences for plant biology, and accurate temperature measurements are therefore important to plant research. Thermography, also referred to as thermal imaging, is beginning to be used more frequently to measure and visualize floral temperature. Accurate thermographic measurements require information about the object’s emissivity (its capacity to emit thermal radiation with temperature), to obtain accurate temperature readings. However, there are currently no published estimates of floral emissivity available. This is most likely to be due to flowers being unsuitable for the most common protocols for emissivity estimation. Instead, researchers have used emissivity estimates collected on vegetative plant tissue when conducting floral thermography, assuming these tissues to have the same emissivity. As floral tissue differs from vegetative tissue, it is unclear how appropriate and accurate these vegetative tissue emissivity estimates are when they are applied to floral tissue.ResultsWe collect floral emissivity estimates using two protocols, using a thermocouple and a water bath, providing a guide for making estimates of floral emissivity that can be carried out without needing specialist equipment (apart from the thermal camera). Both protocols involve measuring the thermal infrared radiation from flowers of a known temperature, providing the required information for emissivity estimation. Floral temperature is known within these protocols using either a thermocouple, or by heating the flowers within a water bath. Emissivity estimates indicate floral emissivity is high, near 1, at least across petals. While the two protocols generally indicated the same trends, the water bath protocol gave more realistic and less variable estimates. While some variation with flower species and location on the flower is observed in emissivity estimates, these are generally small or can be explained as resulting from artefacts of these protocols, relating to thermocouple or water surface contact quality.ConclusionsFloral emissivity appears to be high, and seems quite consistent across most flowers and between species, at least across petals. A value near 1, for example 0.98, is recommended for accurate thermographic measurements of floral temperature. This suggests that the similarly high values based on vegetation emissivity estimates used by previous researchers were appropriate.

Highlights

  • Floral temperature has important consequences for plant biology, and accurate temperature measurements are important to plant research

  • The temperature of plants has a strong influence on their biology [1,2,3,4,5], and this is true in the case of floral temperature [6]

  • In this study we evaluate two methods for obtaining rough estimates of floral emissivity, adapting alternative methods of emissivity estimation applied to other targets [53, 71, 72]

Read more

Summary

Introduction

Floral temperature has important consequences for plant biology, and accurate temperature measurements are important to plant research. Accurate measurement of floral temperature is key to botanical research [6] and may have important applications in Harrap and Rands Plant Methods (2021) 17:23 horticultural industries [33,34,35,36], in monitoring the risk of plant disease and in monitoring the quality of floriculture produce. All objects hotter than absolute zero produce thermal infrared radiation [44, 45] Thermal cameras measure this radiation and use this, along with thermography parameters that are input into the camera, to estimate the temperature of an object [46,47,48,49]. Accurate thermographic temperature estimates depend on accurate estimates of all these thermography parameters, emissivity. As the relationship between temperature and radiation is non-linear [46], the extent of temperature measurement error as a result of emissivity error depends on the true emissivity of the target and the extent of inaccuracy of the emissivity value used

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.