Abstract
Development of the modulation strategy for synchronous control of cascaded inverters, supplied by two strings of photovoltaic panels and connected to a grid by a three-phase transformer with an open winding configuration on primary side, has been done in the paper. Algorithms of synchronized pulsewidth modulation (PWM) are based in this case on continuous control of switching frequencies of two inverters as function of magnitudes of the DC-links voltage. It allows providing both continuous voltage synchronization in each inverter and in the load, and also an improvement of effectiveness of operation of the systems under some operating conditions. Spectral assessment of quality of the phase voltage for the systems with basic versions of synchronized PWM has been performed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.